%0 Journal Article %J Lab on a Chip %D 2017 %T Correction: Double-emulsion drops with ultra-thin shells for capsule templates %A Kim, Shin-Hyun %A Kim, Jin Woong %A Cho, Jun-Cheol %A Weitz, DavidA. %X

Correction for ‘Double-emulsion drops with ultra-thin shells for capsule templates’ by Shin-Hyun Kim et al.Lab Chip, 2011, 11, 3162–3166.

In the section “Diameter and shell thickness of double-emulsion drops” there are errors in eqn (2) and in the sentence that begins “In the same fashion, we calculate the thickness of the middle layer of double-emulsion drops which are produced at each values of Q1/Q2 and plot the results in Fig. 3c”. The equation should be

The sentence should read “In the same fashion, we calculate the thickness of the middle layer of double-emulsion drops which are produced at each values of Q2/Q1 and plot the results in Fig. 3c”.

In the caption for Fig. 3c, “Relative thickness of shell to radius of the double-emulsion drops (t/R) as a function of Q1/Q2.” should read “Relative thickness of shell to radius of the double-emulsion drops (t/R) as a function of Q2/Q1.” In addition, the x-axis is incorrectly labelled with “Q1/Q2”. The x-axis should be “Q2/Q1”. A corrected version of Fig. 3c is shown.

%B Lab on a Chip %V 17 %P 567 %G eng %U https://pubs.rsc.org/en/content/articlelanding/2017/LC/C6LC90129H#!divAbstract %N 3